From d5db46232e87dd23790c99f8460cb3a920e72668 Mon Sep 17 00:00:00 2001 From: Stefan Klug Date: Wed, 26 Jun 2024 12:33:48 +0200 Subject: libtuning: lsc: Prevent negative values In cases where the calibration image contains super dark areas, or when an invalid blacklevel was supplied, the grid might get close to zero or negative. This would have bad effects on the 1/grid later. So clamp the values to a small positive number. Signed-off-by: Stefan Klug Reviewed-by: Laurent Pinchart Reviewed-by: Paul Elder --- utils/tuning/libtuning/modules/lsc/lsc.py | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) (limited to 'utils/tuning/libtuning/modules/lsc/lsc.py') diff --git a/utils/tuning/libtuning/modules/lsc/lsc.py b/utils/tuning/libtuning/modules/lsc/lsc.py index 344a07a3..e0ca22eb 100644 --- a/utils/tuning/libtuning/modules/lsc/lsc.py +++ b/utils/tuning/libtuning/modules/lsc/lsc.py @@ -59,7 +59,10 @@ class LSC(Module): def _lsc_single_channel(self, channel: np.array, image: lt.Image, green_grid: np.array = None): grid = self._get_grid(channel, image.w, image.h) - grid -= image.blacklevel_16 + # Clamp the values to a small positive, so that the following 1/grid + # doesn't produce negative results. + grid = np.maximum(grid - image.blacklevel_16, 0.1) + if green_grid is None: table = np.reshape(1 / grid, self.sector_shape[::-1]) else: -- cgit v1.2.1