summaryrefslogtreecommitdiff
path: root/test/camera
AgeCommit message (Collapse)Author
2019-04-04test: camera: Remove streams argument from configurationValid()Niklas Söderlund
In preparation of reworking how a default configuration is retrieved from a camera remove the streams and validation using the stream when judging if a camera configuration is valid. This is needed as once stream usage hints are added applications will no longer fetch default configuration based on Stream IDs so using them to verify the returned format is not useful. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Jacopo Mondi <jacopo@jmondi.org>
2019-03-14test: camera: Add state machine testNiklas Söderlund
Add a test of the different access level enforced by the state machine inside the camera. The state machine aims to limit operations on the camera to the cameras state. The test exercises all states of the camera and verifies that only the intended operations are possible at each stage. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>
2019-03-14test: camera: Add capture testNiklas Söderlund
Correctly configure the camera using the default configuration and run a capture session for 100 milliseconds, which is plenty of time, in tests over 600 requests completed using the vimc pipeline. The test passes if at least the number of buffers used in the capture times two number of requests completes to prove we cycle through all buffers. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>
2019-03-14test: camera: Add setting of configuration testNiklas Söderlund
Try to set the default configuration, a modified valid configuration and an invalid configuration. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>
2019-03-14test: camera: Add read default configuration testNiklas Söderlund
Add a test to verify reading the default configuration from a camera works. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>