summaryrefslogtreecommitdiff
path: root/test/camera
AgeCommit message (Collapse)Author
2019-05-23libcamera: Use stream roles directly instead of StreamUsageLaurent Pinchart
In order to prepare for an API overhall of the camera configuration generation, remove the StreamUsage class and replace its uses by stream roles. The size hints can't be specified anymore, and will be replaced with an API on the StreamConfiguration to negotiate configuration parameters with cameras. Signed-off-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Jacopo Mondi <jacopo@jmondi.org>
2019-05-23libcamera: camera: Rename configureStreams() and streamConfiguration()Laurent Pinchart
Rename the configureStreams() and streamConfiguration() methods to configure() and generateConfiguration() respectively in order to clarify the API. Both methods deal with CameraConfiguration objects, and are thus not limited to streams, even if a CameraConfiguration currently contains streams only. While at it, remove the qcam MainWindow::configureStreams() method that is declared but never defined or used. Signed-off-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Jacopo Mondi <jacopo@jmondi.org>
2019-04-30test: Unify naming of configurations in testsLaurent Pinchart
Name all instances of CameraConfiguration "config", and all instances of StreamConfiguration "cfg" accross all tests. Signed-off-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Niklas Söderlund <niklas.soderlund@ragnatech.se>
2019-04-30libcamera: Use the Size class through libcameraLaurent Pinchart
Several of our structures include width and height fields that model a size while we have a Size class for that purpose. Use the Size class through libcamera, and give it a toString() method like other geometry and format classes. Signed-off-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Niklas Söderlund <niklas.soderlund@ragnatech.se>
2019-04-09libcamera: Switch to CameraConfigurationNiklas Söderlund
Implement the camera configuration thru out the library, tests, cam and qcam tools. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
2019-04-05libcamera: camera: Add support for stream usagesNiklas Söderlund
Instead of requesting the default configuration for a set of streams where the application has to figure out which streams provided by the camera is best suited for its intended usage, have the library figure this out by using stream usages. The application asks the library for a list of streams and a suggested default configuration for them by supplying a list of stream usages. Once the list is retrieved the application can fine-tune the returned configuration and then try to apply it to the camera. Currently no pipeline handler is prepared to handle stream usages but nor did it make use of the list of Stream IDs which was the previous interface. The main reason for this is that all cameras currently only provide one stream each. This will still be the case but the API will be prepared to expand both pipeline handlers and applications to support streams usages. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
2019-04-04test: camera: Remove test for bad Stream IDsNiklas Söderlund
In preparation of reworking how a default configuration is retrieved from a camera remove test that stream IDs must be valid as the data type passed to Camera::streamConfiguration() will change. This change is in preparation for an invasive change. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Jacopo Mondi <jacopo@jmondi.org>
2019-04-04test: camera: Remove streams argument from configurationValid()Niklas Söderlund
In preparation of reworking how a default configuration is retrieved from a camera remove the streams and validation using the stream when judging if a camera configuration is valid. This is needed as once stream usage hints are added applications will no longer fetch default configuration based on Stream IDs so using them to verify the returned format is not useful. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Jacopo Mondi <jacopo@jmondi.org>
2019-03-14test: camera: Add state machine testNiklas Söderlund
Add a test of the different access level enforced by the state machine inside the camera. The state machine aims to limit operations on the camera to the cameras state. The test exercises all states of the camera and verifies that only the intended operations are possible at each stage. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>
2019-03-14test: camera: Add capture testNiklas Söderlund
Correctly configure the camera using the default configuration and run a capture session for 100 milliseconds, which is plenty of time, in tests over 600 requests completed using the vimc pipeline. The test passes if at least the number of buffers used in the capture times two number of requests completes to prove we cycle through all buffers. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>
2019-03-14test: camera: Add setting of configuration testNiklas Söderlund
Try to set the default configuration, a modified valid configuration and an invalid configuration. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>
2019-03-14test: camera: Add read default configuration testNiklas Söderlund
Add a test to verify reading the default configuration from a camera works. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>